No pin lifting or epoxy removal needed anymore!
Just solder anything on the back according to this picture.
Also if you got status 0×52 instead of 0×72 with the “1,8V-method” this should do it.
I already dumped 4 drives with this method without any issues.
* switch in pos 1
* power drive
* start Dosflash –> SPI should get recognized with status 0×72
* put switch in pos 2
* click “read”
* desolder everything and reconnect the lines that have been cut.

Hope this helps just be careful not to ruin your drives…